General information
In order to determine an exact time, caesium atoms are measured in different energetic states:
The Cs atoms are vaporized in a furnace and magnetically sorted, so that only atoms of a low energetic state reach the so-called cavity resonator. In this cavity the atoms are animated to change their state by irradiation with a microwave field. The atoms that have changed their state are now collected in a special chamber. Since the amount collected is greatest at a certain frequency of the microwave field, the frequency is held and counted.
After exactly 9 192 631 770 periods, one second has finally elapsed.
In the course of a year, the deviation of this clock is a maximum of 25-12 billionths of a second relative to an ideal clock. For a quartz watch, the deviation is a few seconds per month; mechanical wristwatches have significantly larger deviations. There is a special so-called chronometer test for mechanical watches which is passed only with a maximum average deviation of -2 to +4 minutes per month.
History of the atomic clock
In 1946 the world's first atomic clock was presented and in 1949 the National Bureau of Standards (NBS) in Maryland/USA (today NIST) developed an atomic clock using ammonia molecules as vibration source. This atomic clock was already revised in 1952 and now operated using caesium atoms (so-called NBS-1).
In 1955, the National Physical Laboratory presented an even more accurate caesium clock developed by physicists Louis Essen and J. V. L. Parry.
Soon the atomic time was defined as an international standard for the second, since with these clocks incomparably exact gear results could be obtained.
In October 1967, the duration of a second in the international system of units was defined as 9,192,631,770 times the periodic duration of the radiation corresponding to the transition between the two hyperfine structure levels of the ground state of atoms of the 133C nuclide.
Since then, the accuracy of atomic clocks has been continuously improved. Thus, the relative standard deviation to the ideal SI second at the end of the 1990s was about 5*10-15 (corresponds to a deviation of one second in 20 million years).
The newer atomic clocks function on the basis of thermally decelerated atoms in the so-called caesium fountain, in which caesium atoms are cooled down to such an extent that they are only about one centimetre fast per second, which further increases their accuracy.
In the "fountain", the atoms slowed down in this way are finally accelerated upwards by a laser and traverse a ballistic trajectory. With irradiated microwaves, the effective interaction time of the atoms is then extended and a more precise frequency determination is achieved.
Optical clock
The aim is to achieve an even higher measurable accuracy with an atomic clock that works with an optical resonance. This has been the subject of research for several years.
Researchers are approaching this goal with experiments on elements that have suitable transitions at optical wavelengths. In this way, frequencies of hundreds of TeraHz are reached, which are significantly higher than the conventional 9 GHz. A laser is stabilized to a narrow-band transition and individual atoms are stored in an atomic trap. Subsequently, the stability of the frequency of this laser light is transferred with a frequency comb to a periodic electrical signal without loss of accuracy.
The optical atomic clock, which was presented by physicists from JILA in Boulder (Colorado) in February 2008, is based on spin-polarized 87Strontium atoms trapped in a lattice of laser light.
The PTB in Braunschweig has succeeded in verifying a frequency of 429.228.004.229.874 ±1 Hz with the help of its transportable frequency comb.
In cooperation with NIST in Maryland/USA, the precision (not to be confused with accuracy) of an optical atomic clock with spin-polarized atoms (approx. 10000 ytterbium atoms) could be improved to 10-18 at PTB.
In 2012, China also presented an optical clock based on calcium ions developed at the Academy of Sciences in Wuhan.
Small scale atomic clocks
These clocks are developed, for example, for use in satellites of satellite navigation systems such as GPS, GLONASS or Galileo and are intended to help increase positioning accuracy.
A milestone was the development of a Rubidium atomic clock in 2003, which can absorb an electrical power of one watt at a volume of only 40 cm³ (with a relative standard deviation of approx. 3*10¯¹² and thus a deviation of one second in 10,000 years). Although this deviation is much greater than for the large stationary atomic clocks, it is still much more accurate than a quartz clock.